Set-Up Mode (cont.)
4. MANUAL CLEAR/AUTO CLEAR
(Selects The Reset (Clear) Mode For The Display)
a. Press Enter to select this option.
b. Press the Scroll Up key to toggle between Manual Clear ON or
Auto Clear ON.
If the mode is set to Peak or First Peak mode the operation, for Auto Clear, is as follows:
If you turn ON Auto Clear Mode, the display will indicate On x, where x can be 1, 2, 3, 4, 5, 6, 7, 8,
9, or A. A numeric display indicates the time to clear after a peak is reached. For example, On 3
means that the display will clear 3 seconds after reaching a peak value. On A indicates that the dis
play will automatically clear when the TorqueMate® Plus senses that you have applied additional
torque after a peak is reached.
If the mode is set to Power Tool mode the operation, for Auto Clear, is as follows:
If you turn ON Auto Clear Mode, the display will indicate On x, where x can be 1, 2, 3, 4, 5, 6, 7, 8,
or 9. The numeric value indicates the time to clear after a peak is reached. For example, On 1
means that the display will clear 1 second after reaching a peak value.
Note: The time for Auto Clear during Power Tool mode is independent of the timer for Peak or First
Peak.
If in Auto Clear Mode:
c. Press Scroll Up to scroll through the available selections for timing on Auto Clear.
d. Press Enter to save and exit.
5. MEMORY ON/OFF
(Turns on/off the send to memory and RS232 output when in Auto Clear mode).
The Memory On icon will display.
a. Press Enter to select this option.
b. Press the Scroll Up key to toggle between Memory On or Memory OFF.
c. Press Enter to save and exit.
With memory turned On and Auto Clear turned on the display will clear after the Auto Clear timer expires
and the value on the display will be sent to memory as well as out the RS232 port. Note that with these
functions selected the memory of the TorqueMate® Plus may fill rapidly. Note that, when the memory is
full, pressing the Enter key will not clear the display. A beep sound and the No Go indicator will flash
warning the user that no more readings can be accepted into memory. See the CLR function (Item 3)
above for the procedure to clear the data in memory.