Set-Up Mode
Enter the Set-Up mode by pressing the Tolerance and Mode key simultaneously (the Set-Up icon
will turn on). Scroll through the various Set-Up functions by pressing the Scroll Up key. When you get
to the option you want to change press the Enter key. Upon changing any option, you will be returned
to the operation mode.
The following seven paragraphs (DISP, DOWNLOAD, CLR, MANUAL/AUTO CLEAR, TRANSDUCER
CODE, CAL, FIL) is the sequence of functions in the Set-Up menu:
1. DISP - DATA IN MEMORY
(Display The Values Stored In Memory)
DISP and the Data in Memory icon will be shown.
a. Press Enter to select this option.
b. The number of data in memory will be displayed on the large digits.
c. Press the Scroll Right key to view the last data in memory. Press Scroll Up to read the next higher
data number. If the data number has both Torque and Angle associated with it then the TorqueMate®
Plus will first display the torque value and then the Angle (as shown by the Torque or Angle Icon in
the Window).
c. Press the Scroll Right key to read the next lower data number (i.e., 100, 99...98). The Scroll Up key
will not scroll from the last data number to the first (i.e., 100 to 1).
d. Press Enter to exit and return to normal operation.
2. DOWNLOAD DATA IN MEMORY
(Downloads Data In Memory To A Computer or Printer)
Make sure an RS232 cable is attached and press the Enter key to download
data to a computer. The data number will count down on the torque window
as the values are downloaded to a dot matrix printer or computer. Press the
Enter key at any time to stop the transfer of data. Data is sent in the following
stream: Data #, Torque, Units, Angle. The protocol is 8, 1, n at 4800bps.
3. CLR - DATA IN MEMORY
(Clears the data In memory)
a. Press the Enter Key to select the Clear Memory (Clr) option
(Clr flashes on the LCD and the Data in Memory icon is shown).
b. Press the Scroll Right key and the Scroll Up key simultaneously to
clear the memory. Press the Enter key to avoid clearing memory,
and return to the operation mode.
Note: when the memory is full, pressing the Enter key will not clear the display. A beep sound and
the No Go indicator will flash warning the user that no more readings can be accepted into memory.
14